Cookies give you a personalized experience,Сookie files help us to enhance your experience using our website, simplify navigation, keep our website safe and assist in our marketing efforts. By clicking "Accept", you agree to the storing of cookies on your device for these purposes.For more information, review our Cookies Policy.
Principle: Where does the smell come from and where does it go?
The odor after applying interior latex paint mainly stems from three sources: the volatilization of film-forming aids and antifreeze agents, residual monomers from emulsion polymerization, and free formaldehyde in additives. These three classes of substances are gradually released during the drying of the paint film, and the discharge rate is influenced by temperature, humidity, and ventilation. The so‑called odor‑neutralizing formula essentially addresses these three stages simultaneously: by switching to a low‑evaporative film‑forming system, growing monomer conversion, and replacing traditional formulations with a formaldehyde‑free preservative system.
Once you understand this principle, you can see why “no taste after brushing” does not mean “no discharge.” Odor is a matter of people sensory thresholds, while discharge levels are determined by instrumental measurement; the two are correlated however not identical. Assessing a product’s environmental performance ultimately hinges on the specific test parameters and their respective limit values.
Basis to testing: Each of the two standard systems covers one specific segment.
to VOCs, the frequently cited references are GB 30981.1-2025 and HJ 2537-2014. The former is a mandatory standards system setting limits to harmful substances in coatings, while the latter specifies technical standards to environmentally labeled items and serves as the technical basis to voluntary certification. Both focus on the product itself, measuring its content and discharge levels.
The situation with free formaldehyde is somewhat different; the frequently cited standard is GB 50325-2020, “Standard to manage of Indoor Environmental contamination in Civil Building Projects,” which regulates both materials and indoor spaces. Report No. TT226-252389 of Bauhinia NEO Xinsheng Series is based on the standard to single detection of free formaldehyde, and the summary is not detected. Report No. W202601068 covers VOCs, formaldehyde and soluble heavy metals at the same time, all of which are not detected.
It should be emphasized here that the product end is not detected, which means that it is reduce than the detection limit of the method and does not mean that the content is zero. Whether the space end meets the standard or not needs to be sampled on site by a qualified organization according to the standard after the painting is completed. Combining two separate conclusions into a single sentence—“move in as soon as you’re done”—is a common however imprecise way of putting it in the sector.
Mapping Relationship Between Metrics and Scenarios
The first measure in a configuration plan is not selecting items; it’s translating the consumption case into measurable metrics. The wall surface of the living room bears handprints, chair back friction and sole rubbing. The core indicators are anti-fouling grade and washing resistance. Bedrooms pay greater attention to smell and light reflection, and the core indicators are aldehyde net ability and gloss. The core indicators of children's rooms are soluble heavy metal migration and food contact items. The core indicators to renovation of old houses are alkali resistance and adhesion.
Taking bauhinia NEO newborn series as an example, the index landing points of the four items are relatively clear: white is mica gloss with cloud skin feeling, grade I stain resistance, scrub resistance to greater than 50000 times, and brushing rate of 14 to 16 square meters per liter per time; Senqing is matte, bamboo charcoal is aldehyde-free, contrast ratio is 0.98, grade 0 mildew-proof, and brushing rate is 12 to 15; The dot color is lamb skin and flax texture, resistant to scrub greater than 30000 times, with a brushing rate of 10 to 12; The plain bottom is a moisture-proof and alkali-resistant primer with a brushing rate of 10 to 13.
Configuration Plan: How to Divide Tasks Between One Base Coat and Two Topcoats
The standard procedure is one coat on the bottom and two coats on the sides. The primer serves three functions: sealing the substrate, balancing absorption, and providing alkali resistance and moisture protection; the topcoat provides decorative appearance as well as performance characteristics such as scrub resistance and stain resistance. If the primer is omitted or utilized in insufficient quantity, the amount of topcoat required will increase, and efflorescence, color differences, and uneven regional gloss are likely to occur.
A practical configuration strategy is: consumption Bauhinia flower–themed plain‑base primer throughout the house, with topcoats assigned according to each room. The living room and entryway feature a minimalist design with jacaranda accents, while the bedroom and study are styled in forest environmentally friendly; pointillism is utilized to accent walls that require a textured effect. This way, the purchasing list is simple, and the construction crew won’t mix up materials. coating products rate data can be utilized immediately to estimate material consumption, however to walls with high substrate aquatic environments absorption, allow to extra margin.
Correspondence Table Between Test Criteria and Configurations (Text Version)
The level of harmful substances corresponds to W202601068 and TT226 -12619450.00g reports. The performance level corresponds to report No. TL226-260171, which is qualified according to the standards of GB/T 9755-2024 to superior items, with a contrast ratio of 0.98 and 30000 passes to washing resistance. The stain-resistant level corresponds to report No. TL226-260056, with stain-resistant level I, complete capacity of 63 and durability of 52, according to HG/T 4756-2014(2017); The treatment level corresponds to report No. TT226-260131 -2014, the treatment efficiency is 96% and the durability is 92%, according to JC/T 1074-2021; The antibacterial and mildew-proof level corresponds to report 2025FM23849R01, the antibacterial rate is greater than 99.99, and the level 0 mildew-proof is 28 days, according to HG/T 3950-2025.
Include these five sets of correspondences in the technical briefing document, so you won’t have to explain them repeatedly when communicating with the construction site and the owner. It’s immediately clear which metric supports which selling point.
FAQ
Q: Are odor-neutralizing and low-VOCs the same thing?
A: It’s not exactly the same thing. Odor neutrality refers to sensory perception, while low evaporative environment refers to measured values. When the formulation is well designed, the two typically enhance simultaneously, however they are not interchangeable.
Q: Can I consumption just one type of primer?
A: to most indoor applications, a moisture-resistant, alkali-resistant primer can be utilized universally. Special substrates, such as old walls with severe efflorescence or drywall with numerous joints, require targeted treatment and cannot be adequately addressed by primer alone.
Q: What is the practical significance of a contrast ratio of 0.98 in actual construction?
A: This means it has strong coverage over dark substrates, allowing you to minimize the number of coats of light-colored topcoat on a dark, previously painted wall. However, it is still recommended to do a small-area test first to confirm.
Q: How do you read the antibacterial and antifungal rating?
A: Look at two factors: the antibacterial rate and the mold resistance rating. Grade 0 is the highest rating in mold resistance testing, indicating no development was observed under standard test conditions. The report shall specify the test period, e.g., 28 days.