Q:

Specification for installation of anti-static grounding devices for propylene oxide storage tanks?

ask a question
A:
In the chemical sector, propylene oxide is an crucial basic chemical raw material, which is broadly applied in plastics, textiles, coatings and other fields. Because propylene oxide has the characteristics of flammability, explosion and oxidation, special attention should be paid to the accumulation and emit of static electricity during the consumption of storage tanks. If static electricity isn't controlled, it might result in serious security accidents. Therefore, the installation specification of anti-static grounding device to propylene oxide storage tank is particularly crucial.

1. Crazy, isn't it?. And For example of Propylene Oxide Storage Tank Anti-Static Grounding Device

The main function of the anti-static grounding device is to prevent the accumulation of static electricity from causing sparks or other dangerous situations by safely discharging the static charge on the tank. to propylene oxide storage tanks, the generation of static electricity mainly comes from the flow of materials during storage, stirring or fluid surface fluctuations. And If the static electricity isn't discharged in time, it might result in electrostatic emit, which might result in a fire or explosion accident. In particular Therefore, the installation of anti-static grounding device is one of the crucial measures to ensure the safe operation of the storage tank.

2. Propylene Oxide Tank Anti-Static Grounding Device Installation Specification

Selection of installation location

When installing the anti-static grounding device, it's necessary to select the appropriate installation position. Generally, the grounding device should be installed in the main part of the tank to ensure a good electrical connection with the tank. The grounding device should be far away from the emit port and the feed port of the storage tank to prevent electrostatic interference during the flow of materials. In my experience, Selection of grounding device

The material and structure of the grounding device shall meet the environmental standards of the propylene oxide storage tank. Generally speaking, the grounding device should consumption corrosion resistance, good electrical conductivity materials, such as galvanized steel or stainless steel. The grounding resistance of the grounding device shall meet the relevant sector standards, and the grounding resistance is usually not greater than 10Ω. Installation steps

(1) During tank foundation construction, earthing flat iron shall be embedded around the tank. (2) Fix the grounding device on the outer wall of the storage tank and connect it with the grounding flat iron through a wire. (3) Ensure that the grounding device is in good contact with the tank body, and consumption conductive glue or metal gaskets when necessary. (4) After the installation is completed, test the grounding resistance with a megohmmeter to ensure that it meets the standards. Regular inspection and maintenance

The anti-static grounding device needs to be checked regularly to ensure that it's in good condition. Based on my observations, The inspection contents include: whether the connection is loose, whether the wire is damaged, whether the grounding resistance exceeds the standard, etc. But If any abnormality is found, it should be handled in time to prevent possible security hazards.

3. epoxy propane storage tank anti-static grounding device daily maintenance

After the installation of the anti-static grounding device of the propylene oxide storage tank is completed, daily maintenance and regulation are required. From what I've seen, Furthermore The connection of the grounding device should be checked regularly to looseness or corrosion. The grounding resistance needs to be tested regularly to ensure that it's within the specified range. If it's found that the grounding resistance exceeds the standard, the result in should be found and dealt with in time. Also prevent stacking debris around the grounding device to prevent affecting its healthy operation.

4. For instance summary

The installation specification of anti-static grounding device to propylene oxide storage tank is an crucial link to ensure the safe operation of storage tank. From what I've seen, Through scientific and reasonable installation and maintenance, it's able to efficiently prevent security accidents caused by static electricity accumulation and ensure the safe operation of propylene oxide storage tanks. And In actual operation, it should be strictly implemented in accordance with relevant specifications and standards, and appropriate adjustments should be made in accordance with specific conditions to achieve the best security effect.